CMS6600B EMG
Introduction
The equipment records the bioelectrical activity of muscles and nerves to determine their functional status, combining nerve conduction velocity to provide the patient with an auxiliary diagnosis. The items checked include: EMG (electromyogram), MCS (motor nerve conduction velocity), SCS (sensory nerve conduction velocity), F wave, H reflex, repetitive nerve stimulation (RNS), blink reflex, visual evoked potential (VEP), brainstem auditory evoked potential (BAEP), somatosensory evoked potential (SEP), etc.
Main features
Professional platform for EMG/EP operations and full range of tests performed in minimal time
.Neurological and muscular navigation system to easily select the part to be tested
.Powerful normal value system, automatic contrast with normal data
.Flexible software design, configure system parameters as needed
.High-speed data collection, electromagnetic interference suppression, optical isolation and low noise
Integrated hardware system, compact and easy to move

KT88-3200 Digital Brain Electrical Activity Mapping
The KT88-3200 is a digital brain electrical activity mapping device. This equipment records and analyzes the brain's electrical activity to provide a detailed map of its variations. It is used to assess brain function and can be useful in various medical and research fields.
Main features:
Digital Mapping System: The KT88-3200 uses advanced digital mapping technology to record variations in electrical activity in the brain.
Versatility of Tests: It offers a range of tests, including electrical activity mapping, allowing for a thorough assessment of brain function.
Ease of Use: A user-friendly interface allows easy use and understanding of the data obtained.
Comprehensive Analysis: The system analyzes data in real time to provide detailed information on brain electrical activity, which can be essential for diagnosis and research.
Advanced Connectivity: The KT88-3200 features advanced connectivity, enabling communication with other devices and systems, providing complete integration.
Portable Equipment: Compact and easy to transport, this equipment can be used in different medical and research environments.
In summary, the KT88-3200 is an advanced digital brain electrical activity mapping device, offering versatile features and in-depth analysis to assess brain function accurately and effectively.

KT88-2400
The KT88-2400 collects EEG signal with electrodes, through integrated amplification, A/D transformation, PC auto-analysis, FFT, to form an electroencephalogram which is displayed with color depth. The product is applicable for screening diseases such as epilepsy, intracranial inflammation, cerebrovascular diseases and brain tumors.
Main features
10/20 electrode placement method according to the international standard system, leads can be changed during replay. Support different types of leads combined during sampling
Adopt bioelectricity amplifier to distill brain wave, continuous recording time can be up to 24 hours, built-in fully automatic calibration system.
Powerful replay function: The display amplitude and speed are adjustable. The special subdivision timeline divides the waveform in one second into 5 parts, making it easier for doctors to review the waveform.
The digital filter system can be adjusted as needed, providing different types of windows.
EEG signal slicing function, analysis and storage of any section of the EEG wave, and selection of multiple wave segments for automatic analysis and distillation at different parameters.
Electronic frequency ruler, convenient for measuring the basic information of any designated EEG wave. With a partial magnifying window, accurate measurement of EEG period, amplitude and frequency, adjustable according to staff judgment.
Mark the EEG waveform under eye opening, eye closing, and blinking events with different colors, and user-defined events can be added. The waveform color for the evoked event can also be freely set, ensuring that the waveform in the corresponding time can be quickly found by the event name during case replay.
Powerful automatic analysis function, can perform power spectrum analysis and pathological wave detection for a designated wave. Many graphs can be displayed on the same screen, including various types of BEAM, digital BEAM, compressed spectrum graph, trend graph, etc.
Professional isolation transformer, dual power isolation system and optoelectronic data transmission to ensure safety. Use USB interface to transmit data that just needs to be inserted.
Optional multifunctional strobe with USB interface, and flashing can be controlled manually or automatically. A flash stimulation pattern can be set and executed during the sampling process.
Perfect case management function, provides many ways for quick search and statistical information; convenient case export and import function, and storage with MO disk or CD-RW, making data search easier.
Full image and text report, the report can be edited in mode and switched to a Word document.
Case files can be transformed into EDF and BDF data format, convenient for data exchange, academic exchange and further analysis.
System parameters and display modes can be adjusted as needed, meeting the requirements of different users.
Add marks and annotations to the designated wave, which can quickly find the wave at that time by marks.
Optional Video Function: The USB camera is easy to install, convenient to use and accurate to record. With flexible replay function, which can browse the waveform of any time with the corresponding isochronous sampled image. SpO2 function is optional.

KT88
Introduction
The KT88 collects EEG signal with electrodes, through integrated amplification, A/D transformation, PC auto-analysis, FFT, to form an electroencephalogram which is displayed with color depth. The product is applicable for screening diseases such as epilepsy, intracranial inflammation, cerebrovascular diseases and brain tumors.
.Functionality
s· 10/20 electrode placement method according to the international standard system, leads can be changed during replay. Support different types of leads combined during sampling
.· Adopt bioelectricity amplifier to distill brain wave, continuous recording time can be up to 24 hours, built-in fully automatic calibration system
.· Powerful replay function: The display amplitude and speed are adjustable. The special subdivision timeline divides the waveform in one second into 5 parts, making it easier for doctors to review the waveform.
.· The digital filter system can be adjusted as needed, providing different types of windows
.· EEG signal slicing function, analysis and storage of any section of the EEG wave, and selection of multiple wave segments for automatic analysis and distillation at different parameters
.· Electronic frequency ruler, convenient for measuring the basic information of any designated EEG wave. With a partial magnifying window, accurate measurement of EEG period, amplitude and frequency, adjustable according to staff judgment
.· Mark the EEG waveform under eye opening, eye closing, and blinking events with different colors, and user-defined events can be added, the waveform color for the evoked event can also be set freely, ensuring that the waveform in the corresponding time can be quickly found by the event name during case replay
.· Powerful automatic analysis function, can perform power spectrum analysis and pathological wave detection for a designated wave. Many graphs can be displayed on the same screen, including various types of BEAM, digital BEAM, compressed spectrum graph, trend graph, etc.
.· Professional isolation transformer, dual power isolation system and optoelectronic data transmission to ensure safety. Use USB interface to transmit data that just needs to be inserted
.· Optional multifunctional strobe with USB interface, and flashing can be controlled manually or automatically. A flash stimulation pattern can be set and executed during the sampling process
.· Perfect case management function, provides many ways for searching and quick statistical information; convenient case export and import function, and storage with MO disk or CD-RW, making data searching easy
.· Full image and text report, the report can be edited in mode and switched to a Word document
.· Case files can be transformed into EDF and BDF data format, convenient for data exchange, academic exchange and further analysis.
.· System parameters and display modes can be adjusted as needed, meeting the requirements of different users
.· Add marks and annotations to the designated wave, which can quickly find the wave at that time by marks
.· Optional Video Function: The USB camera is easy to install, convenient to use and accurate to record. With flexible playback function, which can browse the wave of any time with the corresponding isochronous sampled image
.· SpO2 function is optional