PM20
Introduction
PM20 portable ECG monitor is an ECG checking device, which is applicable for family and individual use, it is a good assistant to prevent cardiovascular diseases early and reduce risks.
The smart design allows for remote health management using a mobile app. It can automatically start measurement, store ECG, upload data, download health findings, and get medical advice at the first moment.
Features
2.4-inch color TFT-LCD display.
Quick to check ECG once finger touches, convenient to get single or six-lead electrocardiogram.
An accurate conclusion can be obtained immediately after measurement.
The built-in rechargeable lithium battery can continuously record up to 500 cases on a full charge.
Transmission Bluetooth.
ECG data can be saved on the CLOUD platform permanently, convenient for checking and analyzing.
Historical data can be dynamically reviewed, providing a vivid visualization.
Historical data can be printed at any time, facilitating diagnosis.

ECG1201G
Introduction
The device is an electrocardiograph that can simultaneously collect 12-lead ECG signal and print ECG wave with thermal printing system. It features automatic/manual mode recording and display of ECG wave; automatic measurement, analysis and diagnosis of ECG wave parameters; "Disconnection" and "Lack of paper" warnings; optional interface language (Chinese/English, etc.); built-in lithium battery, AC/DC; free choice of rhythm lead to observe abnormal heart rhythm; case database management.
Function
Adopt 7 inch high resolution color LCD screen, operated by buttons, convenient to use.
Synchronous collection for 12-lead ECG, supports 12-lead and Cabrera waveform display. Obtain high-quality ECG waveform via the mains frequency filter (50/60 Hz), baseline filter and EMG filter (25/35 Hz) of the ECG signal.
Display 1/3/6/12 leads of ECG waveform, HR value, print mode, sensitivity, paper speed, filter status, battery power, background grid, etc. on one screen, and with alert functions for disconnection, overload and system running status.
Power Supply: AC/DC (which can adapt to AC 50/60Hz), with built-in rechargeable lithium battery, charging circuit, perfect over-current and over-voltage protection circuit.
In optimal DC state, up to 10 hours of standby time, continuous printing for more than 3 hours, which meets the requirements of patient home visit and body examination.
Built-in thermal printer, supports multiple printing modes, such as auto M×N, M×N 1, M×N 2, rhythmic M line and manual, etc. Contents including time, paper speed, sensitivity, calibration signal, lead name, filter status and patient information can be printed. Printed wave length, measurement parameter output, diagnosis conclusion, superimposed QRS wave, histogram, trend graph and interval list, etc. can be set. With scheduled printing functions, which meet different requirements.
With the functions of automatic measurement and automatic interpretation of common ECG parameters, provide automatic measured results and diagnostic conclusions for HR, PR interval, P duration, QRS duration, QT/QTc interval, P/QRS/T axis, R(V5), S(V1), R(V5) S(V1) amplitude, etc., reducing the workload of the doctor.
Historical cases can be reviewed, queried, edited, forwarded, printed, corrected for derivation, cases can also be exported to other electronic file formats (dat, xml, bmp, png)
Multilingual interface and report.
Support external standard USB keyboard, scanner and printer.

E3M
Introduction
The E3M is an electrocardiograph capable of simultaneously collecting 12-lead ECG signals and printing the ECG waveform with a thermal printing system. Its functions are: recording and displaying the ECG wave in automatic/manual mode; automatic measurement of ECG wave parameters and automatic analysis and diagnosis; detection of pacing ECG; electrode disconnection and paper end warning; optional interface languages (Chinese/English, etc.); built-in lithium battery, powered by either AC or DC power; arbitrary selection of rhythm lead to conveniently observe abnormal heart rhythm; case database management, etc.
Function
nSynchronous collection for 12-lead ECG, adopts digital signal processing technology and obtains high-quality ECG waveform through the line frequency filter, baseline filter and EMG filter of the ECG signal
.Display 1/3/6/12 leads ECG waveform, print mode, sensitivity, paper speed and filter status etc. on one screen, convenient for contrast diagnosis
.Multiple printing modes and formats, including manual, auto 4x3, auto 3x4 1, auto 3x4, auto 2x6 1, auto 2x6, etc. The printed wave length can be adjusted, and with programmed printing function, which meets different requirements.
.With the functions of self-analysis and self-diagnosis of common ECG parameters, reducing the workload of the doctor
.Built-in memory, which is convenient for the doctor to review the case and make statistics
.Multilingual interface and report (Chinese, English)
.Optional ECG-Sync software, connects to PC by USB2.0 interface to form an ECG workstation, imports real-time data into the software for analysis and report printing, and past cases stored in the electrocardiograph can be downloaded to PC
.Power supply: AC/DC and built-in rechargeable lithium battery, meeting the requirements of patient home visit and body examination

E18M
Introduction
The device is an electrocardiograph capable of simultaneously collecting 18-lead ECG signal and printing ECG waveform with thermal printing system. It features automatic/manual mode recording and display of ECG waveform; automatic measurement, analysis and diagnosis of ECG wave parameters; warning of “electrode disconnection” and “paper end”; optional language interface (Chinese/English, etc.); built-in lithium battery, AC/DC; free selection of rhythm lead to observe abnormal heart rhythm; case database management, etc.
Functions
10.1 inch high resolution 1280*800 dots color LCD screen, operation by either touch screen or function buttons, which is convenient and quick.
Synchronous collection for 18-lead ECG, support 18-lead and Cabrera-lead waveform display, adopt digital signal processing technology, and obtain high-quality ECG through line frequency filter, baseline filter, EMG filter and low-pass filter for ECG signals.
Display 3/6/12/18-lead ECG waveforms on one screen, and HR values, print mode, sensitivity, paper speed, filter status, clock, battery level, grid lines, measured data and interpretation information, etc. Reminder function for electrode disconnection and overload, system working status.
The device can be powered by either mains or DC (can adapt to 50/60Hz AC mains frequency), with built-in rechargeable lithium battery and charging circuit, perfect battery overcurrent and overvoltage protection circuit.
.In optimal DC state, up to 10 hours standby time, continuous printing more than 3 hours, recording up to 1000 ECG waveforms (usually it is a 3-second case), which meets the requirements of patient home visit and body examination.
Built-in thermal printer, supports Auto MN, Auto MN 1, Auto MN 2, Auto MN 3, rhythm M line, manual, etc. printing modes and formats. The printed content contains time, paper speed, sensitivity, calibration signal, lead name, filter status, and patient information. Information such as printed wave length, measurement parameter output, diagnostic conclusion, QRS wave overlay, histogram, trend graph, and interval list can be set, with scheduled printing function and automatic arrhythmia printing function, which meet different requirements.
With the functions of automatic measurement and self-interpretation of common ECG parameters, provide the measurement results and self-diagnosis conclusion for HR, PR interval, P duration, QRS duration, T duration, QT/QTc interval, P/QRS/T axis, R(V5), S(V1), R(V5) S(V1) amplitude, etc. which reduces the workload of the doctor.
The built-in large-capacity memory can store at least 4000 medical records, making it easy for doctors to review medical records and collect statistical information.
Historical medical records can be reviewed, viewed, modified, transmitted, printed, corrected, exported to other electronic file formats (dat, pdf, xml, bmp, jpeg, png, etc.)

E12M
Introduction
The device is an electrocardiograph capable of simultaneously collecting 12-lead ECG signal and printing ECG waveform with thermal printing system. It features automatic/manual mode recording and display of ECG waveform; automatic measurement, analysis and diagnosis of ECG wave parameters; warning of “electrode disconnection” and “paper end”; optional language interface (Chinese/English, etc.); built-in lithium battery, AC/DC; free selection of rhythm lead to observe abnormal heart rhythm; case database management, etc.
Functions
10.1 inch high resolution 1280*800 dots color LCD screen, operation by either touch screen or function buttons, which is convenient and quick.
Synchronous collection for 12-lead ECG, support 12-lead and Cabrera-lead waveform display, adopt digital signal processing technology, and obtain high-quality ECG through line frequency filter, baseline filter, EMG filter and low-pass filter for ECG signals.
Display 3/6/12-lead ECG waveforms on one screen, and HR values, print mode, sensitivity, paper speed, filter status, clock, battery level, grid lines, measured data and interpretation information, etc. Reminder function for electrode disconnection and overload, system working status.
The device can be powered by either mains or DC (can adapt to 50/60Hz AC mains frequency), with built-in rechargeable lithium battery and charging circuit, perfect battery overcurrent and overvoltage protection circuit.
In optimal DC state, up to 10 hours standby time, continuous printing more than 3 hours, recording up to 1000 ECG waveforms (usually it is a 3-second case), which meets the requirements of patient home visit and body examination.
Built-in thermal printer, supports Auto MN, Auto MN 1, Auto MN 2, Auto MN 3, rhythm M line, manual, etc. printing modes and formats. The printed content contains time, paper speed, sensitivity, calibration signal, lead name, filter status, and patient information. Information such as printed wave length, measurement parameter output, diagnostic conclusion, QRS wave overlay, histogram, trend graph, and interval list can be set, with scheduled printing function and automatic arrhythmia printing function, which meet different requirements.
With the functions of automatic measurement and self-interpretation of common ECG parameters, provide the measurement results and self-diagnosis conclusion for HR, PR interval, P duration, QRS duration, T duration, QT/QTc interval, P/QRS/T axis, R(V5), S(V1), R(V5) S(V1) amplitude, etc. which reduces the workload of the doctor.
The built-in large-capacity memory can store at least 4000 medical records, making it easy for doctors to review medical records and collect statistical information.
Historical medical records can be reviewed, viewed, modified, transmitted, printed, corrected, exported to other electronic file formats (dat, pdf, xml, bmp, jpeg, png, etc.).
Multilingual interface and report (Chinese, English). Full touch screen with button operation, built-in virtual keyboard, support for Chinese and English input methods.
With Wi-Fi wireless communication function. With LAN and USB cable transmission functions. Automatic case upload, report download and printing.
Support for standard external USB keyboard, mouse, scanner and printer.

E6
Introduction
E6 is a kind of electrocardiograph, which is able to sample 12 leads ECG signals simultaneously and print out the ECG waveform with thermal printing system. Its functions are as follows: recording and displaying ECG waveform in auto/manual mode; measuring ECG waveform parameters automatically, and automatic analysis and diagnosis; pacing ECG detection; prompt for electrode-off and out of paper; optional interface languages (Chinese/English, etc.); built-in lithium battery, powered either by AC or DC; arbitrarily select the rhythm lead to conveniently observe abnormal heart rhythm; case database management, etc.
Note: The device does not support automatic analysis and diagnosis function.
Functions
1) Adopt 7'' high-resolution color LCD, operate by touch screen and function buttons, convenient to use.
2) Sync collection for 12-lead ECG, support routine 12-lead and Cabrera-lead waveform display. Get high-quality ECG waveform via AC filter, DFT filter, EMG filter and Low-pass Filter of ECG signal.
3) Display 3/6/12 - lead ECG waveform, print mode, sensitivity, paper speed, filter status, etc. on one screen, convenient for contrastively diagnosing.
4) Power supply: AC/DC (which can adapt AC 50/60Hz), with built-in rechargeable lithium battery, charging circuit, perfect over-current and over-voltage protection circuit.
5) Support for auto 1*12, auto 2*6, auto 2*6 1, auto 3*4, auto 3*4 1, auto 4*3, auto 4*3 1, auto 6*2, auto 6*2 1, rhythm 7, rhythm 6, rhythm 5, rhythm 4, rhythm 3, rhythm 2 and manual. The printed content contains time, calibration signal, filter status and patient’s information. Information including printed waveform length, output measurement parameters, diagnostic conclusion, superposition QRS wave, histogram, trend chart, interval list, can be set, and with time print function, which meets different requirements.
6) With the functions of auto-measurement and auto-interpretation for routine ECG parameters, provide measurement results for HR, PR interval, P Duration, QRS Duration, T Duration, QT/QTc interval, P/QRS/T Axis, R(V5), S(V1) and R(V5) S(V1), etc. and auto-diagnosis conclusion, which reduces the doctor’s burden.
7) Rhythm lead can be selected freely, convenient to observe abnormal heart rhythm.
8) The subject’s clinical information (such as, ID, Name, Age, Sex, Height, Weight, etc.) can be entered.
9) 1000 cases (3 s case is frequently used) can be stored by the built-in memory, convenient for case review and statistic.
10) In optimal DC state, up to 10-hour standby time, continuous print for more than 3-hour and print up to 1000 ECG waveform (3 s case is frequently used).
11) Multi-language interface and report.
12) External printer and USB storage device can be connected.

E3
Introduction
The E3 device is an electrocardiograph capable of simultaneously collecting a 12-lead ECG signal and printing the ECG waveform with a thermal printing system. Its functions are: automatic/manual ECG waveform recording and display; automatic measurement of ECG wave parameters, and automatic analysis and diagnosis; detection of pacing ECG; warning of “electrode disconnection” and “paper end”; optional multi-language interface (Chinese/English, etc.); built-in lithium battery, powered by either AC or DC power; arbitrary selection of rhythm lead to conveniently observe abnormal heart rhythm; case database management, etc.
Note: The device does not support automatic analysis and diagnosis function.
Functions
High-resolution thermal array output system (8 dots/mm), no adjustment required. Frequency response up to 150 Hz.
Synchronous collection for 12-lead ECG, support 12-lead waveform and Cabrera lead display, adopts digital signal processing technology and obtains high-quality ECG through line frequency filter, DFT filter, EMG filter and low-pass filter for ECG signals.
Display 3/6/12-lead ECG waveforms on one screen, and values of print mode, sensitivity, paper speed, filter status, etc. on one page, convenient for comparative diagnosis.
Supports auto 1×12, auto 1×12 1, auto 2×6, auto 2×6 1, auto 3×4, auto 3×4 1, auto 4×3, auto 3-2 1, auto 3-2, rhythm 4, rhythm 3, rhythm 2 and manual modes. The printed content contains time, paper speed, sensitivity, calibration signal, lead name, filter status and patient information. Information such as printed wave length, measurement parameter output, diagnostic conclusion, superimposed QRS wave, histogram, trend graph and interval list can be set, with scheduled printing function, which meets different requirements.
With the functions of automatic measurement and self-interpretation of common ECG parameters, provide the measurement results for HR, PR interval, P duration, QRS duration, T duration, QT/QTc interval, P/QRS/T axis, R(V5), S(V1) and R(V5) S(V1), etc. and self-diagnosis conclusion, which reduces the workload of the doctor.
Rhythm derivation can be selected freely, convenient to observe abnormal heart rhythm.
Subject's clinical information (such as ID, name, age, gender, height, weight, etc.) can be entered.
1000 cases can be stored by built-in memory, convenient for case review and statistics.
Multilingual interface and report (Chinese, English, Turkish, Portuguese, German, Russian and Kazakh, etc.).
Power Supply: AC/DC (which can adapt to 50/60Hz AC mains frequency), with built-in rechargeable lithium battery, charging circuit, perfect over-current and over-voltage protection circuit.
Can connect with external USB keyboard, code scanner, printer and USB storage device.

CONTEC8000GW ECG Workstation
Introduction :
The device is a sophisticated ECG analysis system designed for medical and healthcare institutions. With the ability to synchronously collect conventional 12-lead ECG data and 3-lead vector ECG data, it offers a range of real-time monitoring, analysis, and diagnostic functions. The system is compact, portable, and equipped with a Bluetooth function for convenient data transmission.
Features:
Compact and Portable Design:
The recorder features a compact and portable design.
Supports Wilson and Frank bypass systems.
Indicator lights provide status notifications for charging, low battery, and Bluetooth mode.
Real-Time Sampling and Analysis:
Adopts real-time sampling, display and storage mode.
Provides real-time QRS wave analysis, heart rate calculation and printing.
Uses multiple filter methods to avoid baseline drift and interference.
Advanced ECG Analysis:
Uses advanced ECG analysis arithmetic for accurate arrhythmia auto-recognition.
Improves the value of analysis reports and conclusions.
Anti-Alias Technology:
The ECG waveform display incorporates anti-aliasing technology.
The intelligent lead position adjustment function solves problems such as waveform overlap due to baseline drift or large amplitude waves.
High Sampling Rate:
A high sampling rate (1000 Hz) ensures a correct ECG waveform without distortion.
High resolution in display and printing ensures accurate details of the ECG waveform.
Display and Print Modes:
Offers dozens of synchronized and continuous display and print modes, including 6x2, 3x4, 3x4 2, etc.
Auxiliary tools such as superimposed waveform analysis, electronic scale and an editable terminology database enhance convenience for diagnosis and clinical applications.
Multiple Analysis Functions:
Supports various analysis functions, including conventional 12-lead ECG, frequency cardiogram (FCG), high-frequency ECG, QT internal dispersion analysis, heart rate variability (HRV) analysis, myocardial ischemia analysis (STLE), heart rate turbulence analysis (HRT), pacing ECG analysis, vector ECG (VCG), time vector ECG (TVCG) and SAECG, etc.
Quick Print Function:
The "quick print" function allows you to preview or print complete analysis reports.
Supports saving reports in multimedia formats (BMP, PNG, PDF or JPG) according to actual needs.
Integration and Connectivity:
Supports calling external procedures to obtain information about patients of unknown origin.
Allows export of ECG data in standard HL7 aECG format.
Facilitates printing electronic reports and sending notifications to external procedures.
Convenient for integration with hospital HIS systems, PACS and other systems.
Battery Life:
The built-in large-capacity rechargeable lithium-ion battery ensures continuous operation for more than 7 hours.

TLC9803 Dynamic ECG Systems
Introduction
Dynamic ECG systems adopt a 3-lead configuration, allowing continuous recording of ECG waveforms for 24 hours and analysis of ECG waveforms via PC software. They are used in medical institutions and communities.
Features
· The recorder can store real-time ECG data for 24 hours.
· Arrhythmia analysis based on MCSSTM and TMCATM can significantly reduce the doctor's workload.
· With more than 10 models (such as atrial premature contraction, ventricular premature contraction, long interval, atrial fibrillation, etc.) and many user-defined modules, it can almost distinguish all types of pathological waves.
· Flexible analysis channel selection function to ensure that all channels can be chosen as the main analysis channel.
· Flexible atrial fibrillation analysis, providing physicians with the use of full or segmented AUTO/manual analysis, which is more accurate in atrial fibrillation analysis.
· All pacemakers (such as AAI, VVI, DDD, etc.) can be analyzed by the powerful pacemaker analysis function.
· With many pacemaker analysis models, such as “Dual Chamber Pacing”, “Atrial Pacing”, “Ventricular Pacing”, “Ventricular Pseudofusion” and “Ventricular Asynchronous Pacing”, etc.
· Rapid analysis allows you to review the ECG of a single lead or all leads at any time.
· Heart rate variability analysis function over 5 minutes, 1 hour and 24 hours.
· One-click printing, convenient and quick to print reports.
· Perfect case management function.
· The risk of sleep apnea can be predicted by the unique analysis function "Sleep Apnea Syndrome".
· The risk of death in patients who have suffered a heart attack can be predicted by the "HRT" (Heart Rate Turbulence) analysis function.
· "T wave alternans" is an important index for predicting malignant arrhythmias and sudden cardiac death.

ECG1212G
Introduction
The device is an electrocardiograph that can simultaneously collect a 12-lead ECG signal and print the ECG wave with a thermal printing system. It features automatic or manual recording and display of ECG wave; automatic measurement, analysis and diagnosis of ECG wave parameters; alerts for "Electrode disconnected" and "Lack of paper"; optional Chinese/English language interface, etc.; built-in lithium battery, AC/DC; freely selectable rhythm lead to observe abnormal heart rhythms; and case database management.
Features
Adopts 10.1 inch high resolution color LCD screen, operated by full touch screen and function buttons, convenient to use.
Synchronized collection for 12-lead ECG, supports display of 12-lead and Cabrera waveforms. Obtain high-quality ECG waveform via mains frequency filter (50/60 Hz), baseline filter and EMG filter (25/35 Hz) of the ECG signal.
Displays 3/6/12-lead ECG waveforms, heart rate (HR) value, print mode, sensitivity, paper speed, filter status, time, battery power, background grid, measured parameters and interpretation, etc., on a single screen, with alert functions for electrode disconnection, overload and system operating status.
Power Supply: AC/DC (can adapt to 50/60Hz AC mains frequency), with built-in rechargeable lithium battery, charging circuit, perfect over-current and over-voltage protection circuit.
In optimal DC condition, standby time up to 10 hours, continuous printing for more than 3 hours, meeting the requirements of home visits and body examinations.
Built-in thermal printer, supporting multiple printing modes and formats, such as auto M × N, M × N 1, M × N 2, rhythm M line and manual mode, etc. Contents including time, paper speed, sensitivity, calibration signal, lead name, filter status and patient information can be printed. Printed wave length, measurement parameter output, diagnostic conclusion, superimposed QRS wave, histogram, trend graph and interval list, etc. can be set. With printing functions (scheduled printing and auto-printing for arrhythmias, etc.), meeting different requirements
With the functions of automatic measurement and self-interpretation of common ECG parameters, providing measured results and self-diagnosis conclusions for Heart Rate (HR), PR interval, P duration, QRS duration, QT/QTc duration, P/QRS/T axis, R(V5), S(V1), R(V5) S(V1) amplitude, etc., reducing the workload of the doctor.
Built-in memory stores at least 4000 cases (data recording time: 10s), convenient for case review and statistics.
Historical cases can be reviewed, queried, edited, forwarded, printed, corrected at the derivation level, and cases can also be exported to other electronic file formats (dat, pdf, xml, bmp, jpeg, etc.)
.· Operating interface, the report in the corresponding language can be printed; built-in virtual keyboard
Support for standard external USB keyboard, mouse, scanner and printer

ECG1200G
Introduction
ECG1200G is an electrocardiograph capable of simultaneously collecting 12-lead ECG signal and printing ECG waveform with thermal printing system. It features recording and displaying ECG waveform in AUTO/Manual mode, automatic measurement and diagnosis of ECG waveform parameters, alerts for "Electrode disconnected" and "Out of paper", multi-language interface, AC/DC, rhythm lead selection, printing trend graph and PR interval histogram for easily observing abnormal heart rhythm, case database management, button operation and touch screen, etc.
Features
· Synchronized collection for 12-lead ECG, 24-bit sampling accuracy achieves high-quality ECG waveform through line frequency filter, baseline filter and EMG filter of ECG signal
.· 3/6/12-lead ECG waveforms and other information such as print mode, sensitivity, paper speed, filter can be displayed on one screen, convenient for comparative diagnosis
.· Multiple printing modes and formats, including auto 12x1, auto 6x2 1 (rhythm lead), auto 6x2, auto 3x4 2 (rhythm lead), rhythm 12, rhythm 10, rhythm 8, rhythm 6, manual, etc. Trend graph and histogram of PR interval can be printed, printed wave length can be adjusted, and with time printing function, meeting different requirements
.· Paper feed speed: 5 mm/s, 6.25 mm/s, 10 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s
.· With self-analysis and self-diagnosis functions of common ECG parameters, providing measurement results and self-diagnosis conclusions for Heart Rate (HR), PR interval, P duration, QRS duration, QT interval, Q-Tc, P axis, QRS axis, T axis, R(V5), S(V1), R(V5) S(V1), etc., reducing the doctor's workload
.· Built-in large capacity memory, convenient for case review and statistics
.· Multilingual interface (Chinese, English, Turkish, Portuguese, German, Russian, Kazakh and other languages) and report
.· In optimal DC state, standby time up to 10 hours, continuous printing for more than 3 hours, meeting the requirements of home visits and body examinations

ECG600G
Introduction
The ECG600G is an electrocardiograph capable of simultaneously collecting a 12-lead ECG signal and printing a waveform using the thermal printing system. It features ECG wave recording and display in AUTO/Manual mode, automatic measurement and diagnosis of ECG wave parameters, alerts for "Electrode disconnected" and "Out of paper", a multilingual interface, and case database management.
.Main Features
Adopts high-resolution thermal printing system (8 dots/mm), requiring no adjustment. Recording frequency: up to 150 Hz
Real-time and continuously records clear and accurate ECG waveform and annotations (including lead mark, sensitivity, paper speed and filter status, etc.).
Fully digital filter design, anti-baseline drift, AC and EMG interference.
Automatically adjusts baseline, optimizes print tuning, and offers optional rhythm leads.
In AUTO mode, complete recording by pressing the button once, improving work efficiency.
Adopts digital signal processing technology and obtains high quality ECG wave through line frequency filter, baseline filter and EMG filter of ECG signal.
With the functions of self-measurement, self-analysis and self-diagnosis of common ECG parameters, reducing the doctor's workload and improving work efficiency.
Synchronized collection for 12-lead ECG, multiple print formats, including 2×6 1 (rhythm lead), 2×6, 3×4, 3×4 1 (rhythm lead), 4×3, 4×3 1 (rhythm lead), 6×2, 6×2 1 (rhythm lead), rhythm 2, rhythm 3, rhythm 4, rhythm 5, rhythm 6, rhythm 7, channel recording, etc.
Real-time display of 3/6/12-lead ECG, "Electrode disconnected" and "Out of paper" on one screen, with ECG DEMO mode. Automatic check and automatic analysis of ECG parameters, ECG wave can be recorded manually or automatically. And patient information can be stored in a case database.
Time printing can be set every 1/2/3/5/10/20/30/60 minutes.
Print setting, including "Print and save" (print waveform and save case), "Print without saving" (print only waveform but do not save case), "Save without printing" (save only case but do not print waveform).
AC/DC, built-in rechargeable lithium battery and automatic protection circuit, and automatic shutdown when no operation within a set period of time.
Stores more than 1000 cases, convenient for case review and statistics.
Multilingual interface and report (Chinese, English, French, Spanish, Turkish, Polish, Italian, German, Portuguese, Kazakh, Russian, Ukrainian, Vietnamese, Serbian, Slovenian and Slovak).

ECG300GT
Introduction
The ECG300GT is an electrocardiograph capable of simultaneously collecting a 12-lead ECG signal and printing a waveform using the thermal printing system. The device can be operated via both the touch screen and buttons. It features recording and displaying the ECG waveform in AUTO/Manual mode, automatic measurement and diagnosis of ECG waveform parameters, alerts for "Electrode disconnected" and "Out of paper", a multilingual interface, and case database management.
.Function
· Synchronized collection for 12-lead ECG, adopts digital signal processing technology and obtains high-quality ECG waveform through line frequency filter, baseline filter and EMG filter of ECG signal
.· Display 3/6/12-lead ECG, print mode, sensitivity, paper speed and filter status, etc. on one screen, convenient for contrast diagnosis
.· Multiple printing modes and formats, including manual, auto 4x3, auto 3x4 1, auto 3x4, auto 2x6 1, auto 2x6, auto 3-2 1, auto 3-2, auto 1x12 1, auto 1x12, rhythm 4, rhythm 3, rhythm 2, etc. The printed wave length can be adjusted, with programmed printing function, meeting different needs
.· With self-analysis and self-diagnosis functions of common ECG parameters, providing measurement results and self-diagnosis conclusion for heart rate, PR interval, P duration, QRS duration, T duration, QT interval, Q-Tc, P axis, QRS axis, T axis, R(V5), S(V1), R(V5) S(V1), etc., reducing the workload of doctor
.· Built-in large capacity memory, storing at least 1000 cases, convenient for doctor to review cases and statistics
.· Multilingual interface and report (Chinese, English, Spanish, Turkish, Polish, Italian, French, German, Portuguese, Russian, Ukrainian, Serbian, Vietnamese, Slovenian, Slovak, Bulgarian and Nigerian languages)

ECG300GA
Introduction
The ECG300GA is an electrocardiograph capable of simultaneously collecting a 12-lead ECG signal and printing a waveform using the thermal printing system. It features recording and displaying the ECG waveform in AUTO/Manual mode, automatic measurement and diagnosis of ECG waveform parameters, alerts for "Electrode disconnected" and "Out of paper", a multilingual interface and case database management.
.Function
Synchronized collection for 12-lead ECG, adopts digital signal processing technology and obtains high-quality ECG waveform through line frequency filter, baseline filter and EMG filter of ECG signal
.Display 1/3/6/12-lead ECG, print mode, sensitivity, paper speed and filter status, etc. on one screen, convenient for contrast diagnosis
.Multiple printing modes and formats, including manual, auto 4x3, auto 3x4 1, auto 3x4, auto 2x6 1, auto 2x6, etc. The printed wave length can be adjusted, with programmed printing function, meeting different needs
.With the self-analysis and self-diagnosis functions of common ECG parameters, providing measurement results and self-diagnosis conclusion for heart rate, PR interval, P duration, QRS duration, T duration, QT interval, Q-Tc, P axis, QRS axis, T axis, R(V5), S(V1), R(V5) S(V1), etc., reducing the workload of the doctor
.Built-in memory storing 15 cases, optional SD card can store up to 100 cases, convenient for case review and statistics
.Multilingual interface and report (Chinese, English)
.Optional ECG-Sync software, connect with PC via USB2.0 interface to form an ECG workstation, import real-time data for analysis and report printing, and download past cases stored in the electrocardiograph to PC
.Power supply: AC/DC and built-in rechargeable lithium battery. In optimal DC state, up to 4 hours standby, continuous printing for 70 minutes and 175 ECGs, meeting the requirements of home visits and body examinations

ECG300G
Introduction
The ECG300G is an electrocardiograph capable of simultaneously collecting a 12-lead ECG signal and printing a waveform using the thermal printing system. It features the recording and display of the ECG waveform in AUTO/Manual mode, automatic measurement and diagnosis of ECG waveform parameters, alerts for "Electrode disconnected" and "Out of paper", a multi-language interface, AC/DC, an optional rhythm lead for easily observing abnormal heart rhythms, and case database management, etc. Note: The device sold in countries and regions requiring FDA certification does not support the automatic analysis and diagnosis function.
Functions
· Synchronized collection for 12-lead ECG, adopts digital signal processing technology and obtains high-quality ECG waveform through line frequency filter, baseline filter and EMG filter of ECG signal.
· Display 3/6/12-lead ECG, print mode, sensitivity, paper speed and filter status, etc. on one screen, convenient for contrast diagnosis.
· Multiple printing modes and formats, including manual, auto 4x3, auto 3x4 1, auto 3x4, auto 2x6 1, auto 2x6, auto 3-2 1, auto 3-2, auto 1x12 1, auto 1x12, rhythm 4, rhythm 3, rhythm 2, etc. The printed wave length can be adjusted, with programmed printing function, meeting different needs.
· With self-analysis and self-diagnosis functions of common ECG parameters, providing measurement results and self-diagnosis conclusion for heart rate, PR interval, P duration, QRS duration, T duration, QT interval, Q-Tc, P axis, QRS axis, T axis, R(V5), S(V1), R(V5) S(V1), etc., reducing the workload of doctor.
· Built-in memory storing at least 1000 cases, convenient for case review and statistics.
· Multilingual interface and report (Chinese, English, Spanish, Turkish, Polish, Italian, French, German, Portuguese, Russian, Ukrainian, Serbian, Vietnamese, Slovenian, Slovak, Bulgarian and Nigerian language).

ECG100G
Introduction
ECG100G is a single-channel electrocardiograph, which is distinguished by printing an ECG wave using a thermal printing system, alerts for "Electrode disconnected" or "Out of paper", multilingual interface, recording the ECG wave in AUTO/Manual mode, easy to use.
Function
· Adopts digital signal processing technology and obtains high quality ECG wave through line frequency filter, baseline filter and EMG filter of ECG signal.
· Adopts high-resolution thermal printing system (8 dots/mm), no adjustment needed. Recording frequency: up to 150 Hz.
· Real-time and continuously record clear and accurate ECG waveform and annotation characters (including lead mark, sensitivity, paper speed and filter status, etc.).
· In AUTO mode, recording is completed by pressing the button once, which improves work efficiency.
· Multilingual interface and report (Chinese, English, French, Italian, German, Spanish, Turkish, Russian and Kazakh).
· In optimal DC state, up to 7 hours standby time, continuous printing up to 4 hours, recording up to 150 ECG waves.