UV-Visible Spectrophotometer


Certifications : CE FCC

Optical System: Single Beam

Light Source: Tungsten lamp and deuterium lamp

Spectral Bandwidth: 2.0 nm

Wavelength Accuracy: ±0.5 nm

Wavelength Repeatability: ≤0.3 nm

Sample Compartment: 4 positions, 10 mm optical path cuvette

Display: LCD screen

Outputs: USB port and Parallel port (Printer)

Power supply: 110/220 V AC, 50/60 Hz, 120 W

Dimensions (L×l×H) : 490×360×210 mm


SP-UV1100

Main Features

• User-friendly operation and information-rich LCD display:

The large, 128 x 64 dot backlit LCD display with adjustable brightness control displays a large amount of data also in graphical form.

• On-board data storage:

The system can save test results, up to 200 data groups and 200 standard curves in RAM memory.

Data can be recovered after a sudden power outage.

• Automatic wavelength adjustment:

Automatically adjust the wavelength to calibrate the system using the arrow keys to avoid operating errors.

• Automatic switching:

Switching between tungsten and deuterium lamps is automatic. Selectable in a wavelength range from 190 to 1100 nm.

• PC control via application software:

The spectrophotometer is fully equipped and capable of performing all functions in stand-alone mode.

The optional 'Wave Professional' application software allows computer control of the spectrophotometer (via the built-in USB port),

in addition to other functions such as spectral scanning, time-domain monitoring (kinetics), multi-wavelength scanning and nucleic acid/protein measurement. (SP-V1100/SP-UV1100)

• Large sampling chamber:

To accommodate 5 to 100 mm optical path cuvettes with optional cuvette holders. A variety of optional accessories are available.


SP-V1100

Main Features

• User-friendly operation and information-rich LCD display:

The large, 128 x 64 dot backlit LCD display with adjustable brightness control displays a large amount of data also in graphical form.

• On-board data storage:

The system can save test results, up to 200 data groups and 200 standard curves in RAM memory.

Data can be recovered after a sudden power outage.

• Automatic wavelength adjustment:

Automatically adjust the wavelength to calibrate the system using the arrow keys to avoid operating errors.

• Large sampling chamber:

To accommodate 5 to 100 mm optical path cuvettes with optional cuvette holders. A variety of optional accessories are available.


SP-UV1000

Main Features

• User-friendly operation and information-rich LCD display:

The large, 128 x 64 dot backlit LCD display with adjustable brightness control displays a large amount of data also in graphical form.

• On-board data storage:

The system can save test results, up to 200 data groups and 200 standard curves in RAM memory.

Data can be recovered after a sudden power outage.

• Automatic wavelength adjustment:

Automatically adjust the wavelength to calibrate the system using the arrow keys to avoid operating errors.

• Automatic switching:

Switching between tungsten and deuterium lamps is automatic. Selectable in a wavelength range from 190 to 1100 nm.

• Large sampling chamber:

To accommodate 5 to 100 mm optical path cuvettes with optional cuvette holders. A variety of optional accessories are available.


SP-V1000

Main Features

• User-friendly operation and information-rich LCD display:

The large, 128 x 64 dot backlit LCD display with adjustable brightness control displays a large amount of data also in graphical form.

• On-board data storage:

The system can save test results, up to 200 data groups and 200 standard curves in RAM memory.

Data can be recovered after a sudden power outage.